149     Manuel „REV“ address high       0     W     1 – 2048             Active if CV 49 Bit 1 = 1

       150     Manuel „REV“ address low        0     W                 Switches to „Reverse drive“ (CV113) (see.
                                                                                   contact input K4)
       151     Manuel „GO“ address high        0     W     1 – 2048     Same effect as CV143/144 as additional

       152      Manuel „GO“ address low        0     W                               switch address
       153    Manuel „SLOW“ address high       0     W     1 – 2048     Same effect as CV146/147 as additional
       154    Manuel „SLOW“ address low        0     W                               switch address
       155     Manuel „REV“ address high       0     W     1 – 2048     Same effect as CV155/156 as additional
       156     Manuel „REV“ address low        0     W                               switch address
       157     Manuel „GO“ address high        0     W     1 – 2048     Same effect as CV143/144 as additional
       158      Manuel „GO“ address low        0     W                               switch address
       159    Manuel „SLOW“ address high       0     W     1 – 2048     Same effect as CV146/147 as additional

       160    Manuel „SLOW“ address low        0     W                               switch address
       161     Manuel „REV“ address high       0     W     1 – 2048     Same effect as CV155/156 as additional
       162     Manuel „REV“ address low        0     W                               switch address
       163      Station stop Adresse hoch      0     W     1 – 2048         Active if CV 49 Bit 1 = 1, Bit 2 = 1
       164       Station stop Adresse tief     0     W                    Manual (de) activation of the station
                                                                         continuation after expiry of CV165/166
       165        Station stop wait time       0     W     1 – 127        Holding time in the braking section in
                                                                                        seconds
                                                                              +128 = Switched on at start
       166     Station stop drive out time     8     W     1 – 127                Exit time in seconds
                                                                                (then stop mode again)
                                                                        +128 = slow travel instead of free travel