Page 135 - Zusammengefügt
P. 135

S = Default, A = Analog operation usable
        CV             Description             S     A      Range                        Note
       120       A1 command allocation         1                                   see attachment 1
                                                                       (if CV 29 Bit 7 = 1, switch address up to 255
                                                                                     (from V. 1.1))
       121          A1 dimming value          255     √                            see attachment 2
       122            A1 condition             0      √                      see attachment 3 (from V. 1.1)
       123         A1 special function         0      √                            see attachment 4
       124     A1 time for special function    5      √    1 – 255              time base (0,1s / value)
       125       A2 command allocation         2                                   see attachment 1
                                                                       (if CV 29 Bit 7 = 1, switch address up to 255
                                                                                     (from V. 1.1))
       126          A2 dimming value          255     √                            see attachment 2
       127            A2 condition             0      √                      see attachment 3 (from V. 1.1)
       128         A2 special function         0      √                            see attachment 4

       129     A2 time for special function    5      √    1 – 255              time base (0,1s / value)


                                         ATTACHMENT 1 – Command allocation
              Value                      Application                                    Note
              0 – 28               0 = Switch with light key                    Only if CV 29 Bit 7 = 0
                                   1 – 28 = Switch with F-key
               +64                      permanent off
               +128                     permanent on


                                            ATTACHMENT 2 – Dimming value
              Value                      Application                                    Note
             0 – 255                    dimming value                         in % (1 % is around 0,2 V)


                                               ATTACHMENT 3 – Condition
              Value                      Application                                     Note
                0                permanent (normal function)
                1                        forward only
                2                       backward only

                3                        standing only
                4                  standing „forward“ only
                5                  standing „backward“ only
                6                        driving only
                7                   driving „forward“ only
                8                  driving „backward“ only


               19                                                                                    LLM
   130   131   132   133   134   135   136   137   138   139   140