Page 113 - Zusammengefügt
P. 113
CV-Table
S = Default, A = Analog operation usable
CV Description S A Range Note
7 Software version – – read only (10 = 1.1)
7 Decoder reset functions
2ranges available 11 basic settings (CV 1,11-13,17-19,29-116)
16 programming lock (CV 15/16)
8 Manufacturer ID 160 – read only
7+8 Register programming mode
CV 7/8 don’t changes his real value
Reg8 = CV-Address CV 8 write first with cv-number, then CV 7
Reg7 = CV-Value write with value or read
(e.g.: CV 49 should have 3)
➔ CV 8 = 49, CV 7 = 3 writing
11 Analog timeout 30 30 – 255 1ms each value
15 Programming lock (key) 240 0 – 255 to lock only change this value
16 Programming lock (lock) 240 0 – 255 changes in CV 16 will change CV 15
113 detection lock after drive in 11 √ 0 – 255 100ms each value
114 power detection 35 √ 1 – 150 value / 10 (35 = 3,5 Amps)
115 detect time 0 √ 0 – 10 0 = permanent else 1 ms each value
116 samples 3 √ 1 – 50 samples for safe current detection
18 KSM